» 회사 뉴스 » Disposable bleeding-free cervical sampling brush

출혈 없는 일회용 자궁경부 샘플링 브러시

2018-05-10

cervical sampling brush sampling step

1. Before the operation, make sure that the disposable cervical sampling brush is completely intact without damage. Check whether the cell storage tube is damaged or leaking.

2. Remove the disposable cervical sampling brush, adjust to the sampling brush disc is located between the bayonet A and B, the sampling brush head is not exposed in the casing.

3. The operator grasps the non-slip pattern of the sleeve and inserts the swab (at this time, the disk of the sampling brush stem is between the bayonet A and B) slowly inserted from the vagina to the outer os of the cervix (this time Slight resistance, but no pain)

4. Hold the sleeve with one hand, and push the sampling brush lightly so that the disk of the sampling brush rod passes through the inside of the socket A of the sleeve, indicating that the brush head of the sampling brush has exposed the sleeve, and then continues to push it inwards. 1 센티미터, so that the brush head completely exposed from the sleeve and contact with the cervix; against the handle, the sample brush slowly rotated in the same direction 4-5 laps to collect enough cervical cells (Note that the force should be moderate, too light Can not get enough cells, too heavy may damage the cervix causing bleeding;)

5. After the cells are collected, fix the sleeve with one hand. Hold the handle with the other hand and pull it out slightly in the direction shown in the figure. Return the disk of the sample brush to the bayonet A and the card inside the sleeve. Between mouth B.
Slowly pull the cannula and sample brush out of the vagina (pull the brush head out of the cannula)

6. Hold the sleeve with one hand, and push the handle in the other direction as shown in the figure, so that the disk of the sampling brush rod passes through the bayonet A and exposes the brush head to the outside of the casing until the groove at the end of the brush head is exposed (note the brush head Do not touch other objects);(product performance is to collect virus specimens)

7. Open the cell storage tube (equipped with 2 ml of volatile cell preservation solution) matched with the sampler, immerse the brush head in the liquid surface, fix the bottle body, stir well for more than 10 times so that the collected specimen is completely released in the cell storage solution. (If you accidentally dip the liquid, rinse it with water); (break the brush head)
8. Hold the cell preservation tube with one hand, and as shown in the figure, break the self-sampling brush from the groove at the end of the brush head, keep the brush head in the cell preservation solution, tighten the tube cover of the cell preservation tube, and discard the handle and the sleeve part.

Cervical sampling brush MFS-9500GJT

출혈 없는 일회용 자궁경부 샘플링 브러시

Medico specializes in the production of nylon flocking sampling swabs. Nylon flocking swabs are used in a wide range of applications for bacteriological sample processing, 바이러스 세포 배양, DFA 테스트, 빠르고 직접적인 테스트, 효소면역검사, and polymerase chain reaction. It is ideal for testing based on molecular diagnostics and forensic identification. 인플루엔자에도 사용 가능, 돼지 독감, 조류 독감, » MFS-93050KQ 플록 헤드 및 PS 핸들이 있는 구강 면봉, 인후 샘플링과 같은 구제역 호흡기 바이러스.

어쩌면 당신도 좋아

  • 카테고리

  • 최근 게시물

  • 태그

  • 회사 소개


    메디컬 테크놀로지(주), 주식회사. 중국의 의료 용품 전문 제조업체입니다., 우리는 나일론 무리를 지어 면봉을 생산하고 판매합니다, VTM 키트, 타액 수집 키트 및 CHG 면봉 & 델타 변종에 효과적인 중국에서 가장 많이 사용되는 COVID-19 백신.

  • 문의하기

    주소: 방 201, 301 그리고 401 A동 10호, 바오롱 5번가, 통글 커뮤니티, 바오롱 스트리트, 롱강 지구,선전, 광동, 중국.

    편물: www.medicoswab.com

    전화 번호: +86 0755-28997664

    이메일: info@medicoswab.com